ALLEN-BRADLEY

CIRCUIT BREAKER MOTOR - MTR PR - 100812141

PN:
100812141
CRN:
140MT-D9N-C10
MPN:
140MT-D9N-C10
Gift wrapping:
Options available

CIRCUIT BREAKER MOTOR - MTR PROTECTOR, D FRAME, 460V, RATED CURRENT 10A, MAG. TRIP ONLY, HIGH BREAKo di regolare la corrente fuori
ción: 1Prohi
decision Prohibido de
ampo de la es
regular la corriente fuera
Внимание! Выставлять уставку в пределах диапазона!
경고:
외부 스케일을 설정하지 마십시오!
24
警告:不要超出刻度值以外进行设置。
1 L1 3 L2 5 L3
Attention: To prevent electrical shock, disconnect from power source before installing
100812141
.RS Legacy # / CRef:
AB
TEST
140MT-D9N-C10
TRIP
In
100812141
CIRCUIT BREAKER MOTOR - MTR PROTECTOR, D FRAME,
10 A
460V. RATED CURRENT 10A, MAG. TRIP ONLY, HIGH
BREAK
140A >>/
140MT-D9N
T3
T2
6
2
T1
4
VanaHner meeressays yarasky s npeasnax ananascual
...... ..
出刻度值以外进行
--
A.B
CAT
SER
140MT-D9N-C10
A
1
Attention: To prevent electrical shock, disconnect from power source before installing
100812141
IEC/EN 60947-2
GB/T 14048.2
CE CA
EAL
RS Legacy # / CRef:
140MT-D9N-C10
http://rok.auto/certifications
Uimp. 6kV
10A
Cal.A
AC-3 50/60Hz
Iph 1 >> 210 A
2ph |>> 140 A
25
cc>Icu
100812141
Icu
Ics
Je
KA
KA
V
9L/OG
CIRCUIT BREAKER MOTOR - MTR PROTECTOR, D FRAME,
max
400
100
IOC
400
3
690
50
$160V, RATED CURRENT 10A, MAG. TRIP ONLY, HIGH
690
6
PUBLI4018-MU-P
140MT-I
CATION NO.
BREAK
No.3
Pozidriv No.2
2 ... 2.5 Nm
8 ... 22 1b-In
20. 3
1270
PN-494498
IP2X
2022/06/03
PRODUCT OF ITALY
Rockwell Automation
1201 S 2nd St, Milwaukee, WI 53204, USA
Bramming Cancionesige regular la corriente fuera
é veraaky a npegenax auan
警告:不要超出刻度值以外进行设置
A
Attention: To prevent electrical shock, disconnect from power source before installing
MAN. MTR. CNTLR. 600V AC
100812141
JUS LISTED
SUITABLE AS MTR. DISCONN
WITH THE LOCKABLE TWIST
MAN. MTR. CNTLR. KNOB 140MT-C-K.
4406
S.C. RATING RMS SYM
65 kA 480V, 30 KA 600V
RS Legacy # / CRef:
SUITABLE FOR MOTOR
GROUP INSTALLATION
140MT-D9N-C10
WHEN PROTECTED BY ANY
CLASS OF FUSES or CB
HAVING CURRENTRATING
LESS THAN OR EQUAL TO
450A/600V
100812141
CIRCUIT BREAKER MOTOR - MTR PROTECTOR, D FRAME,
SUITABLE FOR TAP CONDUCTOR PROTECTION IN GROUP INSTALLATIONS:
S.C. RATING RMS SYM: 65 KA - 240V, 480Y/277V, 30 KA - 600Y/347V
*460V, RATED CURRENT 10A, MAG. TRIP ONLY, HIGH
BREAK
0 FLA MAX,
BREAK ALL LINES
20,
VAC
115
575
HP,3p
-
3
5
7.5
IP. 1ph
0.5
1.5
12902541
00003870

Product attributes

Brand
ALLEN-BRADLEY
crn
140MT-D9N-C10
mpn
140MT-D9N-C10

Not sure which spare part you need?

FORTNA specialists are available 24/7 to assist you in finding even the most elusive genuine OEM replacement parts for nearly any make, any model of equipment. With our extensive knowledge of obsolete and compatible parts, we guarantee that the parts you order through FORTNA will integrate seamlessly with your equipment.