BREAKER, MOTOR PROTECTION, 6.3 - 100500195

PN:
100500195
CRN:
140M-C2E-B63
MPN:
-
Gift wrapping:
Options available

BREAKER, MOTOR PROTECTION, 6.3 A, 3P, 600 V AC, PLASTIC BODY, 1-25/32'' X 2-3/4'' X 3-37/64''Rockwell Automation,
A.B
Bulletin
1201 S 2nd St,
140M
Milwaukee, WI 53204, USA
MOTOR PROTECTOR/CIRC.BREAKER
(MOTOR)
LEISTUNGSSCHALTER
4.0 ... 6.3A
DISJONCTEUR
INTERRUTTORE AUTOMATICO
INTERRUPTOR AUTOMATICO MOTOR
CCC :
CE
LISTED
PN-13388
CAT
PRODUCT OF Switzerland
SER
140M-C2E-B63
C
10662468964354
4030
1936 4
1
L1
3
L2
5
L3
A.B
Class 10
6.3A
-I
11
4.0
[3] 182 A
Test
140M-C2E
2 T1 4 T2 6 T3
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECT
CTRIC SHOCK: IF AN
OVERLOAD
RENT
OR A FAULT
CURRENT
INTERRUPTION
OCCURS. CIRCUITS MUST BE
CKED TO DETERMINE THE
CAUSE
IN A FAULT CON-
DITION. THE
CONTROLLER
SHOULD BE EXAMINED
AND
REPLACED
IF
DAMAGED.TO MAINTAIN
OVERCURRENT. SHORT CIRCUIT AND GROUND FAULT
PROTECTION, THE MANUFACTURER'S INSTRUCTION
FOR SELECTION OF OVERLOAD AND SHORT-CIRCUIT
PROTECTION MUST BE FOLLOWED.
ci
US LISTED
MAN. MTR. CNTLR.
600VAC/SUITABLE AS MTR.
DISCONN. WITH THE LOCKABLE TWIST KNOB 140M-
MAN. MTR. CNTLR.
C-K ... S.C. RATINGS AND CONTROL TRANSFORMER
44D6
SEE INSTRUCTIONS. SUITABLE FOR DESIGN E
MOTORS USE ALL 3 POLES.
AVERTISSEMENT :
POUR LIMITER LE RISQUE D'INCENDIE O
J DE C
: ELEC-
TRIQUE: EN CAS DE COUPURE DUE À UNE SURCHARGE OU À UN
COURANT DE DÉFAUT, LES CIRCUITS DOIVENT ETRE EXAMINES
POUR DÉTERMINER LA
LA CAUSE D'INTERRUTION. DANS LE CAS
D' UN COURANT DE DEFAUT. EXAMINER LE CONTROLEUR ET_LE
REMPLACER S' IL EST ENDOMMANGE. POUR MAINTENIR LA PRO-
TECTION DE SURCOURANT DE COURT-CIRCUIT ET DE DÉFAUT
À LA TERRE, IL EST IMPÉRATIF DE RESPECTER LES INSTRUC-
VAC
115
230 | 46
575
TIONS DU FABRICANT
EN
CHOISSISANT
LES
DIS-
HP,3 ph
-
2
5
5
POSITIFS
DE
PROTECTION
HP,1 ph 0.25 | 0.75
CONTRE LES SURCHARGES
ET LES COURT - CIRCUITS.
0
C CUL
018 3
US LISTED
COMB.
MTR
CNTLR. 85XA
w
MANUAL. SELF-PROTECTED
COMB. MTR. CTRL. WHEN 140M-
C-TE1 OR 140M-C-WTEN OR
140M-C-WBE INSTALLED: 240V,
480Y/277V
6.3 FLA MAX.
when
CONSTRUCTION
BREAK ALL LINES
used
with
TYPE E
TYPE F
DIAL IS FLA
TRIP. AMPS 120%
100-
480V|600V
480V 600V
C09
X
-
-
100
K05
X
Allen-Bradley
Rockwell Automation
1201 South 2nd St.
Milwaukee, WI 53204, USA
Cat
Ser
140M-C2E-B63
C
CE 0102
25
IEC / EN 60947-2 ,- 4-1
GB/T 14048.2/.4
Uimp. 6kV
CCC
6.34
Cat. A
C4.0 ... 6.3A
AC-3
50/60 Hz
II (2) G
1ph [[>>] 123 A
2ph [>>] 82 A
Ue
Icu
Ics
ERC
v
KA
KA
400
100
100
EN 60079-14
PTB 04 ATEX 3039
www.ab.com/certification
690
4
4
Icc> Icu
Ue
gL / gG
V
D max
400
-
690
50A
300 == No. 3
018,3
Pozidriv No. 2
2 ... 2.5 Nm
1936 B1
18 ... 22 1b-in
PN-13388
PRODUCT OF
4030
SWITZERLAND
018
22531646.
비페트

Product attributes

crn
140M-C2E-B63
mpn
-

Not sure which spare part you need?

FORTNA specialists are available 24/7 to assist you in finding even the most elusive genuine OEM replacement parts for nearly any make, any model of equipment. With our extensive knowledge of obsolete and compatible parts, we guarantee that the parts you order through FORTNA will integrate seamlessly with your equipment.