BREAKER, MOTOR PROTECTION, 4.0 AMP, C FRAME, 3-POLE, DIN RAIL MOUNT, 600 VOLT AC, PLASTIC BODYA.B
Bulletin
Rockwell Automation,
1201 S 2nd St,
140M
Milwaukee, WI 53204, USA
MOTOR PROTECTOR/CIRC.BREAKER
(MOTOR)
LEISTUNGSSCHALTER
2.5 ... 4.0A
DISJONCTEUR
INTERRUTTORE AUTOMATICO
INTERRUPTOR AUTOMATICO MOTOR
Ccc.
CE
LISTED
PN-348786
CAT
PRODUCT OF Switzerland
SER
140M-C2E-B40
D
10662468964347
4030
2118 41
L1
3 -
L2
5
L3
A.B
Class 10
-
4.0A
.5
123 152A
Test
140M-C2E
2
T1
4
T2
6
T3WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK: IF AN
OVERLOAD OR A FAULT
CURRENT
R.A .
INTERRUPTION
TS MUST BE
RS. CIRCUITS ML
TERMINE THI
CAUSE. IN A FAULT CON-
DITION. THE
CONTROLLER
SHOULD BE EXAMINED
REPLACED
IF DAMAGED.TO MAINTAIN
OVERCURRENT. SHORT CIRCUIT AND GROUND FAULT
AND
ENT. SHORT
DEDIS INSTRUCTION
PROTECTION. THE MANUFACTURER'S INSTRUCTION
N OF OVERLOAD AND SHORT-CIRCUIT
FOR SELECTION OF OVER
PROTECTION MUST BE FOLLOWED.
CULUS LISTED
MAN. MTR.
CNTLR. 600VAC/SUITABLE AS MTR.
MIR.
ST KNOB 140M-
DISCONN. WITH THE LOCKABLE TWIST HIS
MAN. MTR. CNTLR.
S AND CONTROL TRANSFORMER
C-K ... S.C. RATINGS AND CONTRO
44D6
SEE IN
PLICTIONS.
SUITABLE
E FOR DESIGN E
MOTORS USE ALL 3 POLES.
AVERTISSEMENT :
POUR LIMITER LE RISQUE D'INCENDIE OU DE CHOC ELEC-
TRIQUE: EN CAS DE COUPURE DUE A ON
UNE SURCHARGE OU À UN
COURANT DE DEFAUT, LES CIRCUITS DOIVENT ETRE
POUR DÉTERMINER LA
R LA CAUSE D'INTERRUTION. DANS LE CAS
AMINES
D' UN COURANT DE DÉFAUT, EXAMINER LE
YAMINER LE CONTROLEUR ET L
REMPLACER S' IL E
IL EST ENDÔMMANGÉ. POUR MAINTENIR LA PRO-
TECTION DE SURCOURANT DE COURT-CIRCUIT ET DE DEFAUT
A LA TERRE, IL EST IMPÉRATIF DE RESPECTER LES INSTRUC-
VAC
115
230 | 460 575
TIONS DU FABRICANT
PUOISSIS
EN
CHOISSISANT LES
DIS-
HP,3 ph
1
3
3
POSITIFS
DE
PROTECTION
HP,1 ph| 0.125| 0.33|
CONTRE LES
SURCHARGES
ET LES COURT - CIRCUITS.
UL
016 3
JUS LISTED
w
COMB.
MTR. CNTLR. 85XA
MANUAL. SELF-PROTECTED
MTR. CTRL. WHEN
140M-C-TE1 OR 140M-C-WTEN
OR 140M-C-WBE INSTALLED:
240V, 480Y/277V, 600Y/347V
4.0 FLA MAX.
when
CONSTRUCTION
BREAK ALL LINES
used
TYPE E
TYPE F
DIAL IS FLA
with
480Y, 600Y
TRIP AMPS 120%
100-
80Y |600Y
77V 347V
277V 347V
C09
X
X
-
-
100-
K05
X
X016
10163289644475Allen-Bradley
Rockwell Automation
1201 South 2nd St
Milwaukee, WI 53204, USA
Cat
Ser
140M-C2E-B40
D
IEC / EN 60947-2 ,- 4-1
CE 0102
25
GB/T 14048.2/.4
Uimp. 6kV
CCC
4.04
Cat. A
5 2.5 ... 4.0A
AC-3
50/60 Hz
=
II (2) G
1ph f>>] 78 A
2ph [>>] 52 A
Ue
Icu
Ics
ERC
v
KA
KA
400
CX
100
100
EN 60079-14
www.ab.com/certification
PTB 04 ATEX 3039
690
6
6
Icc> Icu
Ue
gL / gG
V
- max
400
-
690
35A
3 == No. 3
016,3
Pozidriv No. 2
2 ... 2.5 Nm
2118 B1
18 ... 22 1b-in
PN-348786
PRODUCT OF
4030
SWITZERLAND
Not sure which spare part you need?
FORTNA specialists are available 24/7 to assist you in finding even the most elusive genuine OEM replacement parts for nearly any make, any model of equipment. With our extensive knowledge of obsolete and compatible parts, we guarantee that the parts you order through FORTNA will integrate seamlessly with your equipment.